Sign In | Join Free | My ecer.co.uk |
|
Brand Name : Rexroth
Model Number : 4WE6J6X/EW110N9DAL/B08V (R900910382)
MOQ : 1
Price : $418
Payment Terms : T/T,
Supply Ability : >100
Spool symbol : Symbol J
Max. pressure : 350
Electrical connection description : Cable gland, threaded connection 1/2"-14 NPT, with LED
Productgroup ID : 9,10,11,12,13,14
Number of ports : 4
Product typ : with solenoid actuation
Conformity description : CE – Low-Voltage Directive 2014/35/EU CSA approval according to CSA C22.2 No. 139-1982
Size : 6
Electrical connector : Cable gland
Max. flow : 60
Connection diagram : NFPA T3.5.1 R2-2002 D03
Supply voltage : 110…120 VAC
Type of connection : Subplate mounting
Seals : FKM
Number of switching positions 2 : 3
Weight : 1.8
Hydraulic fluid : HL,HLP,HLPD,HVLP,HVLPD,HETG,HEES,HEPG,HFDU,HFDR
Size | 6 | ||
Weight (approx.) | Valve with one actuation cylinder | kg | 2 |
Valve with two actuation cylinders | kg | 2.2 | |
Installation position 1) | any | ||
Ambient temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 |
1) | With version ../O.. (A, C and D) : horizontal |
Size | 6 | ||
Maximum operating pressure | Port P | bar | 315 |
Port A | bar | 315 | |
Port B | bar | 315 | |
Port T 1) | bar | 160 | |
Maximum flow | l/min | 60 | |
Flow cross-section (spool position 0) | Symbol Q | mm2 | approx. 6 % of nominal cross-section |
Symbol W | mm2 | approx. 3 % of nominal cross-section | |
Minimum pilot pressure 2) | bar | 6 | |
Maximum pilot pressure | bar | 200 | |
Pilot volume | cm³ | 1.23 | |
Hydraulic fluid | see table | ||
Hydraulic fluid temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 | |
Viscosity range | mm²/s | 2.8 … 500 | |
Maximum admissible degree of contamination of the hydraulic fluid 3) | Class 20/18/15 according to ISO 4406 (c) | ||
Maximum switching frequency | Hz | 2 |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | 6 ... 10 bar > tank pressure, performance limits dependent on the minimum pilot pressure, see chapter "Diagrams/characteristic curves", section "Performance limits" |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | |
Mineral oil | HL, HLP | FKM, NBR | DIN 51524 | |
Bio-degradable | Insoluble in water | HEES (synthetic esters) | FKM | VDMA 24568 |
HETG (rape seed oil) | FKM, NBR | |||
Soluble in water | HEPG (polyglycols) | FKM | VDMA 24568 | |
Other hydraulic fluids on request |
The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.
Connection voltage (DC voltage) | V | 24 | ||
Voltage tolerance (connection voltage) | +30 %/-15 % | |||
Admissible residual ripple | % | ≤ 10 | ||
Max. load capacity | mA | 400 | ||
Switching outputs | PNP transistor outputs, load between switching outputs and GND | |||
Pinout | 1 | V | 24 | |
2, 4 | Switching output | mA | 400 | |
3 | Earthing (GND) | V | 0 |
For applications outside these parameters, please consult us!
![]() |
Bosch Rexroth Hydraumatic Parts Direct Operated Directional Spool Valve 4WH6GB5X Images |